For example, if the Gen 1 is run on a high setting with HDR photos turned on, we can expect a scan time of roughly 6:10. Note that an RTC360 typically costs 2-3x more than a BLK360. ), Vienna 2005, Vol. 2008; Yaman & Ylmaz 2017; Pawowicz 2018) and yet others have reported on calibration methods for TLS (Lichti & Franke 2005; Rietdorf 2005; Reshetyuk 2006; Schulz 2007; Kern 2008; Kern & Huxhagen 2008; Gottwald et al. 2014), which originates with the publication of Gottwald (2008). (2014)) and Z+F IMAGER 5016 scanning T4 and T2 (right), Panoramic view of the measurement setup for the field test procedure at the Henning-Voscherau-Platz in front of the HCU building (right) according to the setup in Fig. It captures building exteriors, structures, and environments to create 3D point clouds while flying. Blaze through job sites with rapid scanning that doesn't compromise on quality. Compared to all above-mentioned scanners, the Leica BLK360 is a low-cost scanner with minor precision. However, both the comparison of the spatial distances in the test field and horizontal distances at the comparator track with references demonstrated that outliers are in the scanned data set. Leica RTC360 vs. Leica BLK 360 - Laser Scanning Forum Everything You Need to Take Your Skills to the Next Level. - 213.251.185.168. The scanned points belonging to the slab were cropped and a best-fit plane was calculated through all unfiltered point clouds using GOM Inspect software (V8 SR1). Holst et al. The BLK360 G1 is compatible with iPhones and iPads. Inf. Parameter of the two triangles according the setup of the field test procedure (see Fig. 2009; Lindstaedt et al. Subsequent data processing (here comprising of target measurements) was performed in the respective manufacturer software Z+F LaserControl, Leica Cyclone Register 360, and Faro Scene. Everyday carry (EDC) Make your Leica part of your daily routine. ): Leica BLK360, Leica RTC360, Z+F IMAGER 5010, Z+F IMAGER 5016, and Faro Focus3D X330. For the first time, three laser scanners of the same type (Z+F IMAGER 5016) could be examined and compared. DVW-Schriftenreihe 51:1534. The verification of the laser scanners by the field test procedure has shown that all scanners are suitable for use and that with the determined distance differences there are no significant distance and angle deviations in all instruments. 159.65.174.15 Leica Summilux-M 50 f/1.4 ASPH. https://doi.org/10.1007/978-3-030-51953-7_7, Schulz T, Ingensand H. (2004) Influencing variables, precision and accuracy of terrestrial laser scanners. Transitions can be created regardless of the subassembly parameters. Leica BLK360 | Portable 3D Laser Scanner | Datum Tech Solutions Inter. ), Wichmann, VDE Verlag GmbH, Berlin und Offenbach, 284295. Luhmann/Ch. The investigations in the 3D test field provide information about several error components of a laser scanning system, which cannot be determined separately in this test. First, the position of the laser scanner is determined in the coordinate system of the laser tracker to derive the distance DTS between laser tracker and laser scanner. Zeitschrift fr Geodsie, Geoinformation und Landmanagement 2:8896. However, the fitting of the target was only possible up to a distance of 15 m, whilst the fitting of the sphere could only be performed up to a distance of 18 m due to an insufficient scan resolution. BLK360 | Leica Geosystems And that applies to all the different packages. Kersten, T.P., Lindstaedt, M. Geometric accuracy investigations of terrestrial laser scanner systems in the laboratory and in the field. Whilst this parameter was derived in 2019 for the two scanners investigated from the technical specification of the manufacturers, the measurement uncertainty uT of the three scanners was determined in 2020 from multiple measurements of the target centres and a resulting standard deviation of each target centre coordinates (Table 3). A check of the free radius sphere fitting in another software (Geomagic) gave similar results, but with a relatively constant offset of about 4 mm up to the distance of 16 m (Fig. Shop BLK360 Leica BLK360 G1 Scanner 360,000 points of data captured per second 200 ft range for scanning large areas Secure mounting for upright, sideways, or upside down scanning Built-in FLIR sensor captures thermal data Correspondence to 2023All rights reserved It captures spaces with the highest accuracy, enabling the most detailed point cloud files. After capture, ReCap Pro enables point cloud data transfer to a number of CAD, BIM, VR and AR applications. Schematic measurement setup of the field test procedure (left, according to DVW instruction sheet 07-2014 in Neitzel et al. On the track, any distances up to 20 m in length can be realised and determined for measurement from one direction with the laser scanner and from the other direction with the reference measurement system (Leica AT960 laser tracker or Leica TS60 total station). The RTC360 delivers the highest value of all scanners for the distance difference 1.2 with 6.0 mm, but this value is still no indication of a distance deviation because the decisive comparison variable has the same value. ), Wichmann, VDE Verlag GmbH, Berlin und Offenbach, 264275. Matterport & Leica BLK360 G1 Integration The Gen 1 is 165mm in height while the Gen 2 is 155mm in height. Licentiate thesis in Geodesy, Royal Institute of Technology (KTH), Stockholm, 151 pages. $ 19,087.00 The BLK360 G1 is designed to help new-to-LiDAR users capture point clouds and unlock the potential of using them in many different applications. Photogrammetrie Laserscanning Optische 3D-Messtechnik, Wichmann, Heidelberg: 260269. The Art of Home Cinema. Here, the conditions are available to meet all the requirements specified in the DVW instruction sheet as far as possible (Fig. * All accuracies are specified as maximum permissible errors (MPE) and in accordance with ASME B89.4.19-2006 & IS010360-10 using precision Leica 1.5 Red Ring Reflectors up to 60 m distance unless otherwise noted. 11). Anyone who can operate an iPad can now capture the world around them with high resolution 3D panoramic images. https://doi.org/10.1016/j.measurement.2017.07.027, Article BLK360 PRODUCT SPECIFICATIONS GENERAL Imaging scanner 3D scanner with integrated spherical imaging system and thermography panorama sensor system DESIGN & PHYSICAL OPERATION POWER Battery type Capacity Internal, rechargeable Li-Ion battery (Leica GEB212)Typically >40 setups SCANNING IMAGING Camera System Thermal Camera PERFORMANCE Measurement speed HIGH-END TECHNOLOGY IN ULTRA-PORTABLE FORM The Leica Absolute Tracker AT960 from Hexagon Manufacturing Intelligence is the first truly portable dynamic six degrees of freedom (6DoF) laser measurement system. Previously it was required to use a subassembly that could target a path that defined the transition. The action you just performed triggered the security solution. https://www.dgpf.de/pfg/2009/pfg2009-4.html, Lichti DD, Franke J (2005) Self-calibration of the iQsun 880 laser scanner. It can be assumed that these larger deviations at longer distances are caused by an insufficiently precise target fitting of the spheres, since this in part had to be applied several times due to fluctuating results. Leica Geosystems 3D Laser Scanners | TPM Heister H (2006) Zur standardisierten berprfung von terrestrischen Laserscannern (TLS). Although 18 targets were always visible in each scan, only a number between 11 and 13 targets could be fitted per scan station, which resulted in 326 distance combinations. 10. 360,000 laser scan pts/sec ReCap Pro Software: Gain complete access to ReCap Pro for desktop, web, and mobile* Control all aspects of the reality capture process remotely on ReCap for iPad Automatically register and visualize scan data in the field Mark up, tag and collaborate on scans while on the job site 1): the Z+F IMAGER 5016 (2019) from the Hamburg State Office of Criminal Investigation (LKA), the Leica BLK360 (2017), and the Leica RTC360 (2019) from the German engineering company Dr. Hesse und Partner Ingenieure (dhp:i). The Leica BLK360 is a lightweight, compact laser scanner that captures 360-degree images and full-color panoramic photos. A new 3D test field and a 20-m comparator track in the laboratory are used to study and test various laser scanners. Optimize Your Design Process for Greater Efficiency. The initial results of the investigations of the Leica BLK360 on this test field have already been published by Blaskow et al. Leica Instrument Tools - Data Exchange Manager; Exporting Civil3D objects to Leica Captivate DBX format; iCON Field v6.5 - Convert Topcon *.GC3 to Leica Localization . diploma thesis (in German), Institute of Cartography and Geoinformatics, Leibniz University Hannover, http://www.ikg.uni-hannover.de/publikationen/diplomarbeiten/2005/tauber/da_tauber_2005.pdf. https://www.isprs.org/proceedings/XXXVII/congress/5_pdf/182.pdf. Photogrammetrie Laserscanning Optische 3D-Messtechnik, Wichmann, Heidelberg: 5665. (2003), Johansson (2003), Schulz and Ingensand (2004), Tauber (2005), Heister (2006), Neitzel (2006), Bttner and Staiger (2007), Wehmann et al. DVW-Schriftenreihe 66:7794. Mller (Hrsg. Last updated Apr 17, 2023 3:31:44 PM This article examines factors that can affect the fidelity of a Matterport model and takes a deeper look at different use cases. RTC360. On-the-fly image and point cloud processing in the field. Especially test fields, which have an increased space requirement, are primarily found at universities and institutes; in smaller offices this possibility is often not available. Wehmann W, van Zyl C, Kramer H, Widiger D, Zimmermann R (2007) Einrichtung eines Prffeldes zur Genauigkeitsbestimmung von Laserscannern und Untersuchung des Scanners LMS-Z360i der Firma Riegl in diesem Testfeld. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. (2006): Investigation and calibration of pulsed time-of-flight terrestrial laser scanners. Scanning is simple, regardless of whether you are more familiar with Matterport Pro3/Pro2/Pro or the Leica BLK360 G1. Nevertheless, standardised tests and calibration methods of laser scanning systems do not yet exist for the user. The diagram in Fig. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. 11. Measurement Science and Technology, IOP Publishing Ltd. https://doi.org/10.1088/1361-6501/abdae3, Neitzel F (2006) Untersuchung des Achssystems und des Taumelfehlers terrestrischer Laserscanner mit tachymetrischem Messprinzip. Get in contact with our BLK360 sales for more information. Use the up and down arrows to select a result. Now in its third generation, this ABSOLUTE ACCURACY THE RIGHT WAY TO MEASURE WHATEVER THE APPLICATION Driven by the absolute distancing capabilities of the AIFM, the Leica Absolute Tracker AT960 is capable of exceptionally accurate readings across several inspection methods. Luhmann/Ch. Click to reveal Schmitz et al. Optical 3-D Measurement Techniques VII, Gruen & Kahmen (Eds. 2009; Lindstaedt et al. Sr. Dissertation No. The mean value calculated from the distance differences (scanned vs. reference) indicates only a small systematic measurement deviation for each scanner (accept BLK360 with 5.0 mm) in the investigated measurement range of the reference distances (Table 2). Your work is faster, your job is easier, and you get the data you need right away. Read how customers from around the world are putting our diverse solutions into action to shape smart change. Slider with three articles shown per slide. In addition, five laser scanners were tested in accordance with instruction sheet 7-2014 of the German Society for Geodesy, Geoinformation and Land Management (DVW) for standardised testing of terrestrial laser scanners in the outdoor area of HafenCity University Hamburg. Red circles = scanner stations, blue circles = target positions. The BLK360 data is treated differently by each control app. Hexagon (2021) Leica Absolute Tracker AT960. (2003). The new BLK360 is currently not supported. 8 shows the results of the scans to the b/w target. : terrestrial laser scanner Leica BLK360, Leica RTC360, Z+F IMAGER 5010, Z+F IMAGER 5016 in the 3D test field, and b/w target installation. https://www.hexagonmi.com/de-DE/products/laser-tracker-systems/leica-absolute-tracker-at960, last access 05 May 2021. The flatness measurement error is defined as the range of the signed distances of the measurement point from the best-fit plane calculated according to the least-squares method. The remaining targets could not be successfully fitted due to the scan resolution and the long distances in the test field. The original BLK was 100mm in diameter. 11), because both the necessary space for longer horizontal sections and the possibility of an elevated target for the vertical triangle are given. 10). The Leica BLK360 captures the world around you with full-color panoramic images overlaid on a high-accuracy point cloud. Automatically located and tracked by PowerLock, reflectors allow high-speed dynamic measurement in volumes of up to 120 m (). Two passes were scanned for each of the scanners on the comparator track, one to the target and one to the sphere. You can email the site owner to let them know you were blocked. Leica Team: 400+ Service & Application experts; Leica Training: 4-level factory certification program; Leica Logistics: 5 regional hubs for genuine parts Mechelke K, Kersten T, Lindstaedt M (2007) Comparative investigations into the accuracy behaviour of the new generation of terrestrial laser scanning systems. the distances are then measured minimally too long. In contrast, the deviations of the RTC360 (mean value +0.5 mm), the IMAGER 5016 (HCU) (mean value +0.2 mm), and the Faro Focus (mean value +0.7 mm) are all positive with 12 exceptions; i.e. Although the results apply only to the specific instruments in this investigations, they were confirmed in the case of the IMAGER 5016 (HCU) by the tests in 2020. Follow Following Unfollow. Reality capture data connectivity with Autodesks design solutions. A regular examination of the same scanners will then also allow statements to be made about the long-term stability of the scanners examined. Correcting Profile Labels become skewed when dragged. Secondly, the offset between CCR and sphere or target on the carriage has to be determined by measurements to the position of the target/sphere and the CCR point nest. Luhmann/Ch. BLK360. Zeitschrift fr Geodsie, Geoinformation und Landmanagement 3:175180, Wujanz D, Burger M, Tschirschwitz F, Nietzschmann T, Neitzel F, Kersten T (2018) Determination of intensity based stochastic models for terrestrial laser scanners utilising 3D point clouds. Mechelke K, Kersten T, Lindstaedt M (2008) Geometrische Genauigkeitsuntersuchungen neuester terrestrischer Laserscanningsysteme - Leica ScanStation 2 und Z+F IMAGER 5006. Results of the comparison of spatial distances in the test field. In addition to the distance and angular precision of the scanner, the algorithm for target fitting in the respective software also influences the result. The other advantage to the Gen 1 is distance. The reference measurements were realised with the Leica Absolute Tracker AT960 (2017, 2020) and with the Leica TS60 total station (2019). Leica RTC360 3D Laser Scanner | Leica Geosystems The measurements were performed for the scanners in 2019 in about 2 h each and in 2020 in about 3 h each, because six additional targets were scanned at right angles to scan station 1 at distances of 5 to 30 m for the determination of uT. https://doi.org/10.1016/j.matpr.2017.11.304. Workshop on Scanning for Cultural Heritage Recording, Corfu, Greece, 33-38. https://goobi.tib.eu:443/viewer/image/830281592/36/. Interoperability Scan with the BLK360 G1 & Best Practices - Matterport Inf. Now. https://www.research-collection.ethz.ch/bitstream/handle/20.500.11850/10990/eth-29471-02.pdf?sequence=2, Staiger R, Wunderlich T (2006) Terrestrisches Laserscanning 2006 technische Mglichkeiten und Anwendungen. The other IMAGER 5016 (HCU), the IMAGER 5010, and the Faro Focus confirm good results with distance deviation less than 1 mm. 9), because the deviations tend to be negative for all but a few scanners. Optical 3-D Measurement Techniques VII, Gruen/Kahmen (Eds. Holst C, Jurek T, Blome M, Marschel L, Petersen M, Kersten T, Mechelke K, Lindstaedt M, Wehmann W, Wunderlich T, Wasmeier Wiedemann W, Kern F, Kuhlmann H (2018) Empirische Ergebnisse von TLS-Prffeldern: Gibt es Aufflligkeiten? I'm happy to announce that the updated versions of the IMAGINiT content libraries are now available for Civil 3D 2024. In the opinion of the authors, there are only very early publications on the field test procedure (Gottwald 2008; Feldmann et al. Your IP: That same scan run on the Gen 2 would be roughly 1:37. The Gen 2 is not only smaller but is much faster than its predecessor. Ingeo 2004, Bratislava, http://www.geometh-data.ethz.ch/downloads/SchulzT_TS2_Bratislava_2004.pdf, Schulz T (2007) Calibration of terrestrial laser scanner for engineering geodesy. The investigations in the distance measurement accuracy of the Leica BLK360 showed that the manufacturers specifications could be met in most of the scanned distances. Furthermore, the target thickness of 2.03 mm and the radius of the CCR 19.05 mm must be taken into account and added to the offset calculated from the measurements. Since the temperature in the instrument remained constant, the span represents the measurement noise of the instrument, which increases slightly with increasing resolution. Arch. Distance accuracy AIFM +/-0.5 pm/m Environmental working conditions Dust/Water IP54 (IEC 60529) Data output rate 1 000 points/sec Laser safety Class 2 IEC 60825-1 (2014-05) Safety of laser products EN 60825-1 (2007-10) Safety of laser products Leica T-Probe Ux,y,z = +/-35 pm 1 * Additional T-Probe uncertainty to be added according to ISO/IEC Guide 98-3:2008 to So Paulo, BR Lake Forest, US Dallas, US Miamisburg, US Milton Keynes, UK Chester, UK Paris, FR Barcelona, ES Orbassano, IT Unterentfelden, CH Gothenburg, SE St. Petersburg, RU Wetzlar, DE Prague, CZ Ankara, TR Bangalore, IN Qingdao, CN Seoul, KR Atsugi, JP GLOBAL PRESENCE FOR FAST LOCAL RESPONSE Hexagons increasing global presence gives customers guaranteed aftersales support and services, wherever they are in the world. A quiet new approach is proposed by Wujanz et al. This image is a stock photo Leica has on their website so I would like to just show some data I have collected personally. Jays vast experience allows him to help organizations make the most of both Leica Geosystems and Autodesk solutions. Ingensand H, Ryf A, Schulz T (2003) Performances and experiences in terrestrial laser scan. DVW-Schriftenreihe 51:1534. From these target coordinates, distances and finally distance differences were calculated. Spat. https://goobi.tib.eu/viewer/image/856489115/703/. Schumacher (Hrsg. Reshetyuk, Y. Optical 3-D Measurement Techniques VI: 236243. VDI/VDE (2008) Optical 3D-measuring systems multiple view systems based on area scanning. Leica BLK360 G1 3D Imaging Laser Scanner - Kuker-Ranken Anyone who can operate an iPad can now capture the world around them with high resolution 3D panoramic images. Available in a range of types and sizes for various applications, they are compatible with any Leica Absolute Tracker including the AT960. For the measurements to the spheres, the result looks a bit different (Fig. The results of the RTC360 are significantly worse starting at a distance of 15 m with deviations up to 3.2 mm, but for shorter distances the deviations are in the similar range of 1 mm. Distance measurement accuracy on the 20-m comparator track for scans to a b/w target. The results of the field test procedure for the five examined laser scanners Z+F IMAGER 5016 (three systems), Leica RTC 360, and Faro Focus3D X330 are presented in The field test procedure section. Materials today: proceedings 5(1):19972001. The field test procedure took half a day for each of the scanners. Leica BLK360: Accurate Measurements and an Efficient Workflow PowerLock Interrupted line of sight is automatically re-established in a +/-5 degree field of view with no user interaction required for ease of use and exceptional performance in even the most crowded measurement volumes. Three separate independent test methods are presented to investigate the geometric accuracy of terrestrial laser scanners under laboratory conditions: (a) distance measurement accuracy to b/w targets and spheres on the 20-m comparator track, (b) comparison of spatial distances in the 3D test field on b/w targets, and (c) investigation of the flatness deviation following the guideline VDI/VDE 2634 (VDI/VDE 2012) on a flat stone slab. Boehler W, Bordas Vicent M, Marbs, A (2003) Investigating laser scanner accuracy. Photogrammetrie Laserscanning Optische 3D-Messtechnik, Wichmann, Heidelberg: 306316. Pawowicz JA (2018) Impact of physical properties of different materials on the quality of data obtained by means of 3D laser scanning. Not a major issue but something to know about. Voegtle T, Schwab I, Landes T (2008) Influences of different materials on the measurements of a terrestrial laser scanner (TLS). In September 2020, three additional scanners, two IMAGER 5016 and one Faro Focus3D X330, were tested by the field test method. With this movable sledge, distances of 1 to 20 m in meter intervals are realised. Furthermore, the sphere fitting failed at a distance of only 1 m, presumably due to the short distance. 2008; Kersten et al. PRODUCT BROCHURE HEXAGON MANUFACTURING INTELLIGENCE ABSOLUTE PORTABILITY. It was possible to export the determined target coordinates in Z+F LaserControl and in Faro Scene, whilst this option was not available in Leica Cyclone Register 360. The Leica BLK360 G1 is for professionals in architecture, engineering, and related industries. FAQ: Matterport & BLK360 G1 Integration https://doi.org/10.1007/978-3-642-36379-5_3. The Leica Absolute Tracker AT960 - designed to give quicker, more accurate results and a better user experience at the point of production - is the latest product of this approach. With the complete range of All-In-One Design With all the equipment for measurement to a reflector, probing device, laser scanner or machine control unit built in, the compact all-in-one unit is ultra-portable for easy transportation to measure anywhere. Terrestrisches Laserscanning (TLS2008). As many of you know, Leica released the BLK360 Gen 2 last year. For both IMAGER 5016, a maximum shift from 0.0 to +0.5 mm is obtained with an almost ideal and identical normal distribution; the span (as the sum of the absolute maximum negative and positive deviation) of the values is 3.9 mm and 3.8 mm, respectively. Create layers, colors, linetypes and descriptions from an Excel Spreadsheet. Muralikrishnan B, Rachakonda P, Lee V, Shilling M, Sawyer D, Cheok G, Cournoyer L (2017) Relative range error evaluation of terrestrial laser scanners using a plate, a sphere, and a novel dual-sphere-plate target. 3 right). colour will take about 4:20 (or 2:50 if no HDR) greyscale will take about 1:50. point accuracy starts at 6-8mm. Finally, it must be mentioned that the investigations took place at a very early stage of software (ReCap Pro) and hardware (Leica BLK360) development. Cloud Connectivity Kern F (2008) Prfen und Kalibrieren von terrestrischen Laserscannern. For this reason, further investigations should be carried out with other scanners of the same type in order to validate the results obtained here. Dissertation. Using the Control key to modify how polylines are selected in AutoCAD or Civil 3D, Using the Shift key to modify the functionality of the FILLET command in AutoCAD or Civil 3D. BLK360 - What is the accuracy of the camera alignment? Therefore, it is important to use the software associated with the scanner for the target measurements in order to be able to assess the overall system (hardware and software). The measurement setup for the field test procedure could be largely adhered to at this location except for the parameters a2 and a3, as can be seen from the derived parameters of the scan data of the IMAGER 5016 (2019) in Table 4. We undertake measured building surveys on behalf of Architects, typically producing plans, elevations and sections etc. For each scan station, the targets were scanned four times each, taking into account the long distances for the resolution. The manufacturers specified distance measurement accuracy for this BLK360 is 4 mm at 10 m or 7 mm at 20 m. Thus, accuracy for measurement on targets is expected to be in this range or even slightly better. With Hexagons specialist software suites, the AT960 can be optimised for use in a huge range of industries offering a full-system solution to make complicated measurement tasks quick and easy. 13), but this may not be the case everywhere in practice. Use the Previous and Next buttons to navigate the slides or the slide controller buttons at the end to navigate through each slide. This flexible functionality and customisable operation allows operators to select the best method for each application and never compromise accuracy. 4). In the investigations, very good accuracies were achieved for all Z+F IMAGER 5016 tested, which also performed slightly better than the Leica RTC360 in all 2019 test scenarios in the laboratory (3D test field, 20-m comparator track, and planar stone slab). Dimensions of the 3D test field of the HCU Hamburg including distribution of the b/w targets and four scanner positions, F.l.t.r. They propose in their article two methodologies to compute intensity-based stochastic models based on capturing geometric primitives in the form of planar shapes utilising 3D point clouds, which were applied to phase shift and time-of-flight laser scanner. ABSOLUTE SPEED. "While similar to Matterport, the BLK360 is an industry-grade capture device that provides BIM and CAD assets along with Matterport Showcases for visualization. The Leica BLK360 captures the world around you with full-colour panoramic images overlaid on a high-accuracy point cloud. HafenCity University Hamburg (HCU) has been investigating terrestrial laser scanning systems for more than 15 years; since 2016, a more accurate test site has been established at the new building of HCU Hamburg, which can serve as a reference for the increased accuracy level of the new scanners. Based in Stuttgart, Germany, Olaar specialise in architecture, construction and design for a range of indoor and outdoor projects including residential and commercial construction, urban development and concept studies for future builds. Gottwald R (2008) Field procedures for testing terrestrial laser scanners a contribution to a future ISO standard.